
Add to Cart
25kva 40kva Diesel Engine Cummins Generator 30kva Power Generation battery charger ATS deep sea 7320
1. Original Cummins industrial diesel engine
2. Radiator 50°C max, fans are driven by belt, with safety guard
3. Genuine stamford. Leroy somer, marathonm, engga alternator
4. Choice of manual/auto and AMF control panels and protection systems
5. Digital auto-start panel
6. Anti Vibration Suspension Absorber
7. Dry type air filter, fuel filter, oil filter
8. 12 hour operation base tank
Technical Parameter:
Model Number | GNRC150 |
Prime Power | 128KW/160KVA |
Standby Power | 140KW/175KVA |
Original Engine Model | 6CTA8.3-G2 |
Cylinder Type | In-line 6 cylinders |
Displacement | 8.3L |
Induction System | Exhaust Turbocharging,Water-Air Intercooler |
Fuel System | PB fuel pump |
Bore x Stroke | 114*135 |
Compression Ratio | 17.3:1 |
Rated Speed | 1500rpm |
Maximum Power of Original Engine | 180KW/244HP |
Speed Governing System | high degree of accuracy electronic speed governing system |
Exhaust Smoke Level | 34.7m3/min |
Exhaust Gas Temperature | 570°C |
The maximum allowable exhaust back pressure | 10kPa |
The maximum allowable inlet pressure | 6kPa |
Volume of fuel gas | 12.4m3/min |
Air flow | 238m3/min |
100% Loading Fuel Consumption | 40L/H |
Lub. Capacity | 27.6L |
Oil Consumption | ≤4g/kwh |
Oil Pan Capacity | 24L |
Oil Pressure under rated speed | 276-414kPa |
Coolant Capacity(engine and radiator) | 24L |
Alternator(Stamford) | UCI274F |
Alternator(Marathon) | MP-120-4 |
Alternator(Engga) | EG225L-120N |
Output | 3 |
Excitation | Brushless self |
Control system:
1 a) Automatic alarm system: the unit has the acousto-optics alarm system and arrestor for any situation as the start defeat, the water is over temperature, the oil pulls down, over speed, over load and over current
b) Operation display:
i) Unit voltage, tri-phase load current and frequency display
ii) Water temperature, oil pressure display
iii) Fuel level, fuel temperature display
iv) Audible and visual alarm lamps and buzzers
2 Starting system: DC alternator is used to start engine
3 Short circuit protection: MCCB air switch
Standard Accessory
Common steel base frame, Damper, Exhaust silencer, Flexible pipe, Battery and connecting wires, Operation manual and document.
Optional Accessory
Engine coolant and oil heater, Alternator space heater, Cooling for heat exchanger, Battery charger by main supply, Fuel-water separator, Daily fuel tank, ATS & paralleling system, and Moving Trailer.
Soundproof/Silent Box:
1. Excellent ventilation
2. Oil tank mounted on base frame for 12 Hours working
3. Highly Corrosion Resistant construction
4. 1m<80 dB / 7m<70dB