Add to Cart
perkins water cooled diesel engine 10kva generator fuel consumption
perkins diesel generator set | ||
GEN-SETS | Model | GNRP10 |
Engine Brand | UK Brand | |
Rated Output(kva) | 10 | |
Current(A) | 14.4 | |
Power factor(cosφ) | 0.8 | |
Frequency(hz) | 50/60 | |
Fuel Consumption(g/kw.h) | ≤252 | |
The regulating rate of instantaneous voltage | ≤-10%/ +15% | |
The time of steady voltage | ≤1.5sec | |
The waving rate of voltage | ≤0.5% | |
The regulating rate of steady frequency | ≤3% | |
The regulating rate of instantaneous frequency | ≤±5% | |
The time of steady frequency | 3sec | |
The waving rate of frequency | ≤0.25% | |
Dim L×W×H(mm) | 1200X700X1100 | |
Weight(kg) | 300 | |
Diesel engine | Engine model | 403D-11G |
Cylinder | 3 | |
Bore*Stroke(mm) | 77*81 | |
Lubricating oil capacity | 4.9 | |
Rated speed(rpm) | 1500/1800 | |
Cooling method | Closed water cooling | |
Starting system | Electrical start | |
Displacement(L) | 1.13 | |
Alternator | Brand | Stamford/Marathon/Engga |
Type | Brushiess | |
The connecting way of the phase | Three phases four lines | |
Insulation degree | H degree | |
Grading Protection | IP23 |
Control system:
a) Automatic alarm system: the unit has the acousto-optics alarm system and
arrestor for any situation asthe start defeat, the water is over temperature, the oil
pulls down, over speed, over load and over current
b) Operation display:
i) Unit voltage, tri-phase load current and frequency display
ii) Water temperature, oil pressure display
iii) Fuel level, fuel temperature display
iv) Audible and visual alarm lamps and buzzers